Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 56(3): 735-56, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21239845

RESUMO

This study investigates the physical limitations involved in the extraction of accurate timing information from pixellated scintillation detectors for positron emission tomography (PET). Accurate physical modeling of the scintillation detection process, from scintillation light generation through detection, is devised and performed for varying detector attributes, such as the crystal element length, light yield, decay time and surface treatment. The dependence of light output and time resolution on these attributes, as well as on the photon interaction depth (DoI) of the annihilation quanta within the crystal volume, is studied and compared with experimental results. A theoretical background which highlights the importance of different time blurring factors for instantaneous ('ideal') and exponential ('realistic') scintillation decay is developed and compared with simulated data. For the case of a realistic scintillator, our experimental and simulation findings suggest that dependence of detector performance on DoI is more evident for crystal elements with rough ('as cut') compared to polished surfaces (maximum observed difference of 64% (25%) and 22% (19%) in simulation (measurement) for light output and time resolution, respectively). Furthermore we observe distinct trends of the detector performance dependence on detector element length and surface treatment. For short crystals (3 × 3 × 5 mm(3)) an improvement in light output and time resolution for 'as cut' compared to polished crystals is observed (3% (7%) and 9% (9%) for simulation (measurement), respectively). The trend is reversed for longer crystals (3 × 3 × 20 mm(3)) and an improvement in light output and time uncertainty for polished compared to 'as cut' crystals is observed (36% (6%) and 40% (20%) for simulation (measurement), respectively). The results of this study are used to guide the design of PET detectors with combined time of flight (ToF) and DoI features.


Assuntos
Modelos Teóricos , Contagem de Cintilação/métodos , Método de Monte Carlo , Fótons , Tomografia por Emissão de Pósitrons , Fatores de Tempo
2.
Med Phys ; 37(11): 5838-49, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21158296

RESUMO

PURPOSE: This study aims to address design considerations of a high resolution, high sensitivity positron emission tomography scanner dedicated to breast imaging. METHODS: The methodology uses a detailed Monte Carlo model of the system structures to obtain a quantitative evaluation of several performance parameters. Special focus was given to the effect of dense mechanical structures designed to provide mechanical robustness and thermal regulation to the minuscule and temperature sensitive detectors. RESULTS: For the energies of interest around the photopeak (450-700 keV energy window), the simulation results predict a 6.5% reduction in the single photon detection efficiency and a 12.5% reduction in the coincidence photon detection efficiency in the case that the mechanical structures are interspersed between the detectors. However for lower energies, a substantial increase in the number of detected events (approximately 14% and 7% for singles at a 100-200 keV energy window and coincidences at a lower energy threshold of 100 keV, respectively) was observed with the presence of these structures due to backscatter. The number of photon events that involve multiple interactions in various crystal elements is also affected by the presence of the structures. For photon events involving multiple interactions among various crystal elements, the coincidence photon sensitivity is reduced by as much as 20% for a point source at the center of the field of view. There is no observable effect on the intrinsic and the reconstructed spatial resolution and spatial resolution uniformity. CONCLUSIONS: Mechanical structures can have a considerable effect on system sensitivity, especially for systems processing multi-interaction photon events. This effect, however, does not impact the spatial resolution. Various mechanical structure designs are currently under evaluation in order to achieve optimum trade-off between temperature stability, accurate detector positioning, and minimum influence on system performance.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Tomografia por Emissão de Pósitrons/métodos , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Humanos , Método de Monte Carlo , Fótons , Reprodutibilidade dos Testes , Espalhamento de Radiação , Temperatura , Fatores de Tempo
3.
Phys Med Biol ; 53(9): 2391-411, 2008 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-18421120

RESUMO

Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Simulated singles list-mode data of the MADPET-II small animal PET scanner were used as input. The simulations have been performed using the GATE simulation toolkit. Several sources with different geometries have been employed. We evaluated the number of random events using three methods: delayed window (DW), singles rate (SR) and time histogram fitting (TH). Since the GATE simulations allow random and true coincidences to be distinguished, a comparison between the number of random coincidences estimated using the standard methods and the number obtained using GATE was performed. An overestimation in the number of random events was observed using the DW and SR methods. This overestimation decreases for LETs higher than 255 keV. It is additionally reduced when the single events which have undergone a Compton interaction in crystals before being detected are removed from the data. These two observations lead us to infer that the overestimation is due to inter-crystal scatter. The effect of this mismatch in the reconstructed images is important for quantification because it leads to an underestimation of activity. This was shown using a hot-cold-background source with 3.7 MBq total activity in the background region and a 1.59 MBq total activity in the hot region. For both 200 keV and 400 keV LET, an overestimation of random coincidences for the DW and SR methods was observed, resulting in approximately 1.5% or more (at 200 keV LET: 1.7% for DW and 7% for SR) and less than 1% (at 400 keV LET: both methods) underestimation of activity within the background region. In almost all cases, images obtained by compensating for random events in the reconstruction algorithm were better in terms of quantification than the images made with precorrected data.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Computadores , Cristalização , Desenho de Equipamento , Imageamento Tridimensional/métodos , Modelos Estatísticos , Modelos Teóricos , Método de Monte Carlo , Distribuição Aleatória , Reprodutibilidade dos Testes , Espalhamento de Radiação , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Phys Med Biol ; 50(14): 3323-35, 2005 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-16177512

RESUMO

We present a unique data acquisition system designed to read out signals from the MADPET-II small animal LSO-APD PET tomograph. The scanner consists of 36 independent detector modules arranged in a dual-radial layer ring (phi 71 mm). Each module contains a 4 x 8 array of optically isolated, 2 x 2 mm LSO crystals, coupled one-to-one to a 32 channel APD. To take full advantage of the detector geometry, signals from each crystal are individually processed without any data reduction. This is realized using custom designed mixed-signal ASICs for analogue signal processing, and FPGAs to control the digitization of analogue signals and subsequent multiplexing. Analogue to digital converters (ADCs) digitize the signal peak height, time to digital converters (TDCs) time stamp each event relative to a system clock and two 32 bit words containing the energy, time and position information for each singles event are multiplexed through three FIFO stages before being written to disk via gigabit Ethernet. Every singles event is processed and stored in list-mode format, and coincidences are sorted post-acquisition in software. The 1152 channel data acquisition system was designed to be able to handle sustained data rates of up to 11 520 000 cps without loss (10 000 cps/channel). The timing resolution of the TDC was measured to be 1 ns FWHM. In addition to describing the data acquisition system, performance measurements made using a 128-channel detector prototype will be presented.


Assuntos
Lutécio , Tomografia por Emissão de Pósitrons/instrumentação , Silicatos , Animais , Imagens de Fantasmas
5.
Phys Med Biol ; 49(2): 271-85, 2004 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15083671

RESUMO

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.


Assuntos
Câmaras gama , Animais , Simulação por Computador , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Espalhamento de Radiação , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...